Calculate the effective glazed area for each space from the architectural model so that spaces with insufficient daylight are identified before the permit submission.

Starting point

  • Window openings cannot be used directly as effective glazed areas because frames and opaque infill reduce the transparent portion.
  • Without an unambiguous space assignment, windows can be allocated to the wrong space or counted more than once.

Goal & benefit

  • Compare the net glazed area of each space with its floor area in a traceable manner.
  • Identify deviations from the agreed cantonal or project-specific limits at an early stage.

Process

  1. Provide interior spaces with stable room numbers and net areas, and exterior windows with geometrically separated transparent glazing.
  2. Assign each exterior window to the geometrically adjacent or nearest interior space, write back the space reference, and calculate the projected net glazed area; report missing or ambiguous assignments.
  3. Sum the glazed areas for each space, divide them by the net space floor area, and compare the ratio with the limit configured for the project.

Deliverable

  • Architectural model with a traceable space assignment and net glazed area for each exterior window.
  • Space-by-space verification report showing glazed area, floor area, ratio, limit, and deviations.

Ways to do it

  • ClimateStudio Solemma editorial listing

    Daylight, glare and energy simulation as a plug-in for Rhino.

    Visit vendor · last checked

  • DIALux evo DIAL editorial listing

    Lighting and daylight design with manufacturer luminaire data, calculation and visualisation.

    Visit vendor · last checked

  • Ladybug Tools Ladybug Tools editorial listing

    Open-source Grasshopper plug-ins for climate, daylight and energy simulation (Ladybug, Honeybee).

    Visit vendor · last checked

  • vyzn vyzn AG editorial listing

    Model-based building analysis for LCA to SIA 2032/KBOB, energy to SIA 380/1, daylight and early costs.

    Visit vendor · last checked

Suggest a tool All tools and services

Elements involved

More use cases for Permit certainty

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel