Use

Laboratory and research

USE-LA pragmaticBIM.ch/use-la

Experimental research and analysis. Reference quantity: number of lab workstations.

Boundary conditions

PG-29Laboratory type

Wet and dry labs differ in water and drainage connections, ventilation, and surfaces.

Variants

  • LBA-01Wet lab

    Work with liquids and chemicals at sinks and fume hoods.

  • LBA-02Dry lab

    Work at instruments, measuring stations, and computers.

PG-28Safety level

The biosafety level (BSL) and the number of lab workstations and fume hoods determine access, ventilation, pressure cascades, and wastewater.

Variants

  • BSL-01BSL 1

    No or negligible risk.

  • BSL-02BSL 2

    Low risk; biosafety cabinets and controlled access.

  • BSL-03BSL 3

    Moderate risk; airlock, negative pressure, and filtered exhaust.

  • BSL-04BSL 4

    High risk; fully contained laboratory area.

PG-42Fume hood density

Fume hood density determines extract airflow, shafts, and how deep the lab workstations are.

Variants

  • AZD-01none

    No fume hood at the lab workstation.

  • AZD-02low

    For example fewer than 0.5 fume hoods per lab workstation.

  • AZD-03high

    At least 1 fume hood per lab workstation.

  • PG-15Refit frequency

    How often spaces, equipment, and installations are refitted decides how current the as-built data must be in operation. The more often the building is refitted, the more facility management use cases are preselected.

Scenarios

US-LA-06Reaching the laboratory

Researchers, samples, and supplies reach the laboratory floors. The access arrangement determines access control, hazardous goods transport, and separation of people and material routes.

Variants

US-GE-01Reaching the unit (Described under another use)

US-LA-01Running experiments

Researchers carry out tests, measurements, and analyses. The laboratory type determines ventilation, media supply, and safety level.

Variants

US-GE-03Disposing of waste (Described under another use)

US-LA-02Storing samples and supplies

Samples, reagents, and consumables are kept until use. Storage conditions determine temperature, access, and traceability.

Variants

US-LA-03Handling hazardous substances

Chemicals and hazardous substances are delivered, stored, and disposed of. Separate stores determine fire compartments, ventilation, and routes through the building.

Variants

US-LA-07Changing in the laboratory

Staff put on protective clothing before entering the laboratory zone. The location determines contamination protection and routes in laboratory clothing.

Variants

US-LA-05Evaluating results

Researchers analyse data and write reports outside the lab. Separate write-up spaces determine lab area, safety, and team exchange.

Variants

US-LA-09Disposing of special waste

Researchers take hazardous laboratory waste away separately from other waste. The kind determines ventilation, shielding, and the route out of the building.

Variants · Several can be selected

US-LA-08Emergency power

Experiments, refrigerated samples, and fume cupboards have to keep running during a power cut. Emergency power determines whether a dedicated generator is needed, and with it the plant area and the fire compartment.

Variants

Use cases

More uses

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel