Room type Housing

Balcony

RT-WH-15 pragmaticBIM.ch/rt-wh-15

Open exterior space attached to the dwelling.

Room name code

RN-11-10-01 Balcony

Standard values

Exterior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon TRUE
LongName Balcony
Reference Pset_SpaceCommon ANF
NetPlannedArea ePset_SpaceRequirement 4 m²
FloorCovering Pset_SpaceCoveringRequirements Concrete
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace EXTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN
PredefinedType SPACE
IsExternal Pset_SpaceCommon TRUE
LongName Balcony
Reference Pset_SpaceCommon ANF
NetPlannedArea ePset_SpaceRequirement 8 m²
FloorCovering Pset_SpaceCoveringRequirements Concrete
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace EXTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN
PredefinedType SPACE
IsExternal Pset_SpaceCommon TRUE
LongName Balcony
Reference Pset_SpaceCommon ANF
NetPlannedArea ePset_SpaceRequirement 12 m²
FloorCovering Pset_SpaceCoveringRequirements Concrete
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace EXTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN

Equipment

Outdoor socket outlet
  • preferred · elevation
min. 1, 1 per 10 m² net floor area
Light switch
  • required · elevation
1
Outdoor socket outlet
  • preferred · elevation
min. 1, 1 per 10 m² net floor area
Light switch
  • required · elevation
1
Outdoor socket outlet
  • preferred · elevation
min. 1, 1 per 10 m² net floor area
Light switch
  • required · elevation
1

Openings

French window 1 (min. 1)
French window 1 (min. 1)
French window 1 (min. 1)