Mail room
RT-WH-14
pragmaticBIM.ch/rt-wh-14
Room for receiving and distributing mail.
Room name code
RN-10-20-02 Mail room
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Mail room | |
| Reference Pset_SpaceCommon | NNF | |
| NetPlannedArea ePset_SpaceRequirement | 4 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Restricted | |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
Equipment
| Lockers | 1 |
Socket outlet
|
min. 1, 1 per 10 m² net floor area |
Light switch
|
1 |