Boundary condition Boundary conditions
Accessibility
PG-39
pragmaticBIM.ch/pg-39
This framework condition sets how far the building is accessible beyond the legal minimum under SIA 500: adaptable or wheelchair-accessible throughout. It drives doors, spaces, and circulation.
Variants
-
HIN-01Minimum under SIA 500
Publicly accessible areas and circulation meet the basic requirements under SIA 500 and cantonal law.
Activates: Verify accessibility to SIA 500
-
HIN-02Adaptable
Dwellings and workplaces can be adapted for wheelchair use without work on the structure or services. Door widths and manoeuvring areas are designed for it from the start.
Activates: Verify accessibility to SIA 500, Derive the basis for door planning
-
HIN-03Wheelchair-accessible throughout
All spaces can be used in a wheelchair without adaptation. Sanitary rooms, kitchens, and fittings are designed for wheelchair use and agreed with users.
Activates: Verify accessibility to SIA 500, Derive the basis for door planning, Coordinate sanitary fixtures, Verify furnishability
Activated use cases
DES · Design
-
DES-DOORDerive the basis for door planning
Derive the door-design basis from the model so that door schedules and discipline coordination do not rely on scattered individual details.
-
DES-SANITARY-FIXTURE-COORDCoordinate sanitary fixtures
Coordinate sanitary fixtures jointly, from first placement through to detailed plumbing design, so that connections and service linings match the approved locations and dimensions.
QAS · Quality assurance
-
QAS-ACCESS-SIA500Verify accessibility to SIA 500
Make deviations from the accessible route visible before the permit submission, instead of discovering them only during the permit procedure.
-
QAS-FURNISHABILITYVerify furnishability
Prove furnishability of interior rooms so clients can decide and approve without being able to read plans.
More boundary conditions
-
PG-37
Indoor climate
This framework condition sets whether spaces are only heated, also cooled, or controlled for temperature and humidity. It drives the room types with their target values, the building services, and with them plant areas, shafts, and storey heights.
-
PG-34
Energy standard
This framework condition sets whether the building meets the legal minimum or reaches a standard such as Minergie, Minergie-P, or Minergie-A. The standard drives exterior walls, roofs, windows, and the airtightness of the envelope.
-
PG-35
Greenhouse gas target
This framework condition sets the limit for grey energy and greenhouse gas emissions from construction, separate from operational energy. The target drives material choice for every component type.