Boundary condition Boundary conditions
Greenhouse gas target
PG-35
pragmaticBIM.ch/pg-35
This framework condition sets the limit for grey energy and greenhouse gas emissions from construction, separate from operational energy. The target drives material choice for every component type.
Variants
-
THG-01No target
No limit applies to grey energy and greenhouse gas emissions from construction.
-
THG-02SIA 390/1 guide value
Greenhouse gas emissions from construction stay within the climate path guide value under SIA 390/1. Construction volume and life-cycle assessment are calculated from the model.
Activates: Determine the construction volume, Calculate the life-cycle assessment, Check component types against performance requirements
-
THG-03Tightened target
The client sets a limit below the guide value. Every component type gets a target for grey energy and greenhouse gases.
Activates: Determine the construction volume, Calculate the life-cycle assessment, Check component types against performance requirements
Activated use cases
DES · Design
-
DES-KVDetermine the construction volume
Derive construction volume from gross volume, net spaces, and air spaces so material use can be compared already in early phases.
-
DES-LCACalculate the life-cycle assessment
Carry component quantities, materials, and product class so LCA and grey energy via KBOB are possible without parallel quantity lists: early via the product class, later refined by the calculated type.
QAS · Quality assurance
-
QAS-ELEMENT-PERFCheck component types against performance requirements
Check wall, slab, window, and door component types against the performance requirements that follow from the chosen framework conditions, so every type demonstrably meets what was ordered.
More boundary conditions
-
PG-38
Sound insulation
This framework condition sets whether the minimum requirements under SIA 181 apply, or increased or special requirements. It drives partitions, slabs, and doors between dwellings or units.
-
PG-33
Earthquake
This framework condition sets the structure class under SIA 261 and, in a renovation, how far the existing structure is upgraded under SIA 269/8. It matters mainly when the client raises it or decides the degree of upgrading.
-
PG-11
Construction method & prefabrication
This framework condition determines whether the construction method remains open, is designed conventionally, or targets a high degree of prefabrication in timber, steel, or concrete. This choice determines when contractors must be involved, interfaces resolved, and shop, production, and assembly information provided.