Boundary condition Boundary conditions
Energy standard
PG-34
pragmaticBIM.ch/pg-34
This framework condition sets whether the building meets the legal minimum or reaches a standard such as Minergie, Minergie-P, or Minergie-A. The standard drives exterior walls, roofs, windows, and the airtightness of the envelope.
Variants
-
ENE-01Legal minimum
Requirements under cantonal energy law (MuKEn) and SIA 380/1, verified with the energy certificate for the permit application.
Activates: Derive the basis for heating demand verification to SIA 380/1 from the model
-
ENE-02Minergie
A well-insulated envelope, controlled air exchange, and renewable heat generation. The values of envelope components are set and checked in a building physics concept.
Activates: Derive the basis for heating demand verification to SIA 380/1 from the model, Create the building physics requirements model, Check component types against performance requirements
-
ENE-03Minergie-P
Very low heating demand with a particularly airtight envelope. Thermal bridges and airtightness are verified for every envelope component.
Activates: Derive the basis for heating demand verification to SIA 380/1 from the model, Create the building physics requirements model, Check component types against performance requirements
-
ENE-04Minergie-A
Over the year, the building generates at least as much energy as it uses. Roof and facade are also designed for electricity generation.
Activates: Derive the basis for heating demand verification to SIA 380/1 from the model, Create the building physics requirements model, Check component types against performance requirements, Maintain the facade in the model
Activated use cases
DES · Design
-
DES-ABSTRACTBIM-BPSDerive the basis for heating demand verification to SIA 380/1 from the model
Derive the basis for heating demand verification to SIA 380/1 from the architecture model without manually remodelling the thermal envelope.
-
DES-PHYSICSCreate the building physics requirements model
Translate the approved building physics concept into a spatially assigned requirements model so sound and thermal insulation can be checked unambiguously and continuously in the architecture model.
-
DES-FACADEMaintain the facade in the model
Maintain the building envelope in the model - simple build-ups as a multi-layer component, complex build-ups with individually modelled facade layers.
QAS · Quality assurance
-
QAS-ELEMENT-PERFCheck component types against performance requirements
Check wall, slab, window, and door component types against the performance requirements that follow from the chosen framework conditions, so every type demonstrably meets what was ordered.
More boundary conditions
-
PG-35
Greenhouse gas target
This framework condition sets the limit for grey energy and greenhouse gas emissions from construction, separate from operational energy. The target drives material choice for every component type.
-
PG-38
Sound insulation
This framework condition sets whether the minimum requirements under SIA 181 apply, or increased or special requirements. It drives partitions, slabs, and doors between dwellings or units.
-
PG-33
Earthquake
This framework condition sets the structure class under SIA 261 and, in a renovation, how far the existing structure is upgraded under SIA 269/8. It matters mainly when the client raises it or decides the degree of upgrading.