Boundary condition Boundary conditions
Working with existing buildings
PG-06
pragmaticBIM.ch/pg-06
This framework condition determines which existing-condition information is procured: spatial reference and terrain only; those plus the building mass and structural shell; or structural shell, fit-out, and MEP.
Explanation
The brief defines the expected result and limits surveying and modelling to the scope the project actually needs.
Variants
-
EXIST-01Spatial reference and terrain
Procure reference points, position and elevation reference, terrain, and the required survey documents.
Activates: Procure the spatial reference and terrain
-
EXIST-02Building and structural shell
First capture the existing building as a point cloud, then selectively model the building and structural shell once the concept direction is clear.
Activates: Procure the spatial reference and terrain, Capture the existing building as a point cloud, Model the building and structural shell for the chosen concept, Procure existing-condition information for circularity, Plan measures for hazardous-material findings
-
EXIST-03Structural shell, fit-out, and MEP
Additionally procure a coordinated existing-condition model of the structural shell, fit-out, and MEP for conversion or change of use.
Activates: Procure the spatial reference and terrain, Capture the existing building as a point cloud, Model the building and structural shell for the chosen concept, Procure existing-condition information for circularity, Procure the existing structural shell, fit-out, and MEP model, Plan measures for hazardous-material findings
Activated use cases
BES · Ordering
-
BES-EXISTING-SITEProcure the spatial reference and terrain
Procure the spatial reference and terrain as a binding design basis so that every discipline model uses the same coordinates, elevations, and parcel information.
-
BES-EXISTING-POINT-CLOUDCapture the existing building as a point cloud
Capture the built condition early as a georeferenced point cloud without rebuilding a complete existing-condition model before the concept direction is clear.
-
BES-EXISTING-STRUCTUREModel the building and structural shell for the chosen concept
Once the concept direction is clear, the client orders a georeferenced existing-condition model of the building and structural shell, limited to the areas relevant to the concept, so that conversion, deconstruction, or extension rest on checked existing-condition information and no unnecessary areas are paid for.
-
BES-EXISTING-CIRCULARITYProcure existing-condition information for circularity
Procure circularity information as a targeted extension of the existing-condition model so that reuse, remediation, and recovery can be assessed early.
-
QAS-HAZMAT-CHECKPlan measures for hazardous-material findings
Assign hazardous-material findings to the affected existing components and use them as a basis for planning remediation, deconstruction, and protection measures.
-
BES-EXISTING-BUILDING-MEPProcure the existing structural shell, fit-out, and MEP model
Procure a coordinated existing-condition model of the structural shell, fit-out, and MEP so that conversion and change of use rely on known components, equipment, and networks.
More boundary conditions
-
PG-02
Use & fit-out standard
This framework condition determines which uses the building accommodates and which fit-out standard applies to which spaces. It is the basis for designing spaces to suit their use and for checking the agreed requirements traceably.
-
PG-39
Accessibility
This framework condition sets how far the building is accessible beyond the legal minimum under SIA 500: adaptable or wheelchair-accessible throughout. It drives doors, spaces, and circulation.
-
PG-37
Indoor climate
This framework condition sets whether spaces are only heated, also cooled, or controlled for temperature and humidity. It drives the room types with their target values, the building services, and with them plant areas, shafts, and storey heights.