Room type Assembly and culture

Stage

RT-CO-13 pragmaticBIM.ch/rt-co-13

Area for performances, including its backstage zone.

Room name code

RN-07-40-01 Stage

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Stage
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 100 m²
FloorCovering Pset_SpaceCoveringRequirements Parkett
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Wood ceiling lining
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Internal
WinterTemperatureMin ePset_SpaceRequirement 18 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 500 lx
PeakOccupancy ePset_SpaceRequirement 20 Personen
DailyOperatingHours ePset_SpaceRequirement 4 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 600 m³/h

Equipment

Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

More room types of this use

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel