Room type Assembly and culture

Cloakroom

RT-CO-15 pragmaticBIM.ch/rt-co-15

Room for depositing visitors' coats and bags.

Room name code

RN-07-40-03 Cloakroom

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Cloakroom
Reference Pset_SpaceCommon NNF
NetPlannedArea ePset_SpaceRequirement 20 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Gypsum board ceiling
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 3 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN
SecurityLevel ePset_Space Internal
WinterTemperatureMin ePset_SpaceRequirement 18 °C
WinterTemperatureMax ePset_SpaceRequirement 22 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 200 lx
PeakOccupancy ePset_SpaceRequirement 4 Personen
DailyOperatingHours ePset_SpaceRequirement 2 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 120 m³/h

Equipment

Service counter 1
Entrance wardrobe min. 1, 1 per 5 m² net floor area
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
  • preferred · next to · serving (≤ 1 m)
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1