Control of exclusion zones and structural sketch
QAS-EXCL-ZONE · General · Quality assurance
Verify the exclusion zone model and structural sketch in the federated model - before planning runs into restricted zones.
Starting point
- The structural engineer delivers the structural concept as a sketch, not a model; the architect still needs reliable structural geometry in the architecture model.
- Without binding exclusion zones and early checks, components get planned in no-go zones - leading to costly follow-up changes.
Goal & benefit
- Maintain the structural concept as a rough structural sketch in the architecture model and mark it as load-bearing.
- Verify the structural engineer's exclusion zone model as a binding planning boundary and document the proof.
Process
- The structural engineer delivers the exclusion zone model; the architect transfers the structural concept as a rough sketch into the architecture model (LoadBearing=TRUE).
- Merge both models in the federated model.
- Verify that architecture geometry and other disciplines do not violate the exclusion zones; document the proof.
Outcome
- Verified compliance with exclusion zones as the planning basis for design development and permitting.
Deliverables
- Architecture model with structural sketch as IfcFooting, IfcSlab, IfcRoof, IfcColumn, and IfcBeam with LoadBearing=TRUE
- Structural engineering exclusion zone model as IfcBuildingElementProxy with PredefinedType=USERDEFINED and ObjectType=Sperrzone
- IfcProject, IfcSite, IfcBuilding, and IfcBuildingStorey in both models
- Name and Reference per element
Activated by project goals
- Schedule criticality · high