Break room
RT-WR-05
pragmaticBIM.ch/rt-wr-05
Informal staff rest and refreshment space.
Room name code
RN-02-20-03 Break room
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Break room | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 25 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Linoleum | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Mineral-fibre acoustic ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 3 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Internal | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 200 | lx |
| PeakOccupancy ePset_SpaceRequirement | 8 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 2 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 240 | m³/h |
Equipment
| Single-row kitchen | 1 |
| Dining table | min. 1, 1 per 12 m² net floor area |
Socket outlet
|
min. 1, 1 per 10 m² net floor area |
Light switch
|
1 |
Openings
| Interior swing door or Interior sliding door | 1 |
| Window | 1 (min. 0) |