Production hall
RT-IN-02
pragmaticBIM.ch/rt-in-02
Hall for manufacturing processes.
Room name code
RN-08-10-02 Production hall
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Production hall | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 1000 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Beton | |
| WallCovering Pset_SpaceCoveringRequirements | Beton roh | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal panel ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Workshop | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Internal | |
| PeakOccupancy ePset_SpaceRequirement | 8 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 10 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 240 | m³/h |
Equipment
| Machine space | min. 1, 1 per 50 m² net floor area |
| Work table | min. 0, 1 per 100 m² net floor area |
Socket outlet
|
min. 1, 1 per 10 m² net floor area |
Light switch
|
1 |
Openings
| Interior double door | 2 (1-4) |
| Gate | 1 (1-4) |
| Window | 1 (min. 1) |