Room type Retail

Pickup point

RT-CO-17 pragmaticBIM.ch/rt-co-17

Counter or area where customers collect goods ordered or bought in advance.

Room name code

RN-07-20-06 Pickup point

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Pickup point
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 10 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Public
WinterTemperatureMin ePset_SpaceRequirement 18 °C
WinterTemperatureMax ePset_SpaceRequirement 22 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 300 lx
PeakOccupancy ePset_SpaceRequirement 2 Personen
DailyOperatingHours ePset_SpaceRequirement 10 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 60 m³/h

Equipment

Lockers min. 1, 1 per 3 m² net floor area
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1