Room type Food service

Bar

RT-CO-03 pragmaticBIM.ch/rt-co-03

Room for beverage service.

Room name code

RN-07-10-03 Bar

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Bar
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 60 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Gypsum board ceiling
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Public
WinterTemperatureMin ePset_SpaceRequirement 20 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 22 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 200 lx
PeakOccupancy ePset_SpaceRequirement 50 Personen
DailyOperatingHours ePset_SpaceRequirement 8 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 1500 m³/h

Equipment

Service counter 1
Bistro table min. 0, 1 per 6 m² net floor area
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
  • preferred · next to · serving (≤ 1 m)
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

More room types of this use