Room type Food service

Commercial kitchen

RT-CO-11 pragmaticBIM.ch/rt-co-11

Kitchen for commercial food preparation.

Room name code

RN-07-10-05 Commercial kitchen

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Commercial kitchen
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 60 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Plattenbelag
CeilingCovering Pset_SpaceCoveringRequirements Gypsum board ceiling
VibrationRequirements ePset_SpaceRequirement ISO Workshop
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Restricted
WinterTemperatureMin ePset_SpaceRequirement 18 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 500 lx
PeakOccupancy ePset_SpaceRequirement 8 Personen
DailyOperatingHours ePset_SpaceRequirement 10 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 240 m³/h

Equipment

Commercial cooking line 1
Work table min. 1, 1 per 15 m² net floor area
Washbasin 1
Shelf 2 (1-4)
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
  • preferred · next to · kitchen (≤ 1 m)
  • preferred · elevation
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

More room types of this use

Contact

abstract ag