QA fire protection component values
QAS-FIRE · General · Quality assurance
Maintain fire resistance classes in the architecture model from the end of the building project phase and check them against the fire protection concept.
Starting point
- Fire requirements for walls, slabs, openings, and load-bearing parts often exist only in reports; values are missing in the model.
- Without consistent component data, verification and tendering are error-prone.
Goal & benefit
- The architect enters fire resistance classes (VKF) on the governing components.
- Fire protection planning can check values and gaps directly on the model.
Process
- Define the fire protection concept and required fire resistance classes.
- The architect enters FireRating, Status, and PredefinedType on walls, slabs, windows, doors, columns, and beams.
- Align values with the fire protection concept and permit documents.
Outcome
- Architecture model with traceable fire resistance data as the basis for fire protection QA.
Deliverables
- Architecture model with IfcWall (exterior and non-load-bearing interior walls), IfcSlab (FLOOR), IfcWindow, IfcDoor, IfcColumn, and IfcBeam
- FireRating, Status, and PredefinedType per component
- IfcProject, IfcSite, IfcBuilding, and IfcBuildingStorey