Room type

Riser

RT-VO-02 pragmaticBIM.ch/rt-vo-02

Vertical building services riser.

Room name code

RN-12-10-02 Riser

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Riser
Reference Pset_SpaceCommon FF
NetPlannedArea ePset_SpaceRequirement 2 m²
FloorCovering Pset_SpaceCoveringRequirements Beton
WallCovering Pset_SpaceCoveringRequirements Beton roh
CeilingCovering Pset_SpaceCoveringRequirements Other / unknown ceiling covering
VibrationRequirements ePset_SpaceRequirement ISO Workshop
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Restricted
PeakOccupancy ePset_SpaceRequirement 1 Personen
DailyOperatingHours ePset_SpaceRequirement 1 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 30 m³/h

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel