Room type Assembly and culture

Archive room

RT-ST-05 pragmaticBIM.ch/rt-st-05

Room for document and record archives.

Room name code

RN-10-20-01 Archive room

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Archive room
Reference Pset_SpaceCommon NNF
NetPlannedArea ePset_SpaceRequirement 30 m²
FloorCovering Pset_SpaceCoveringRequirements Beton
WallCovering Pset_SpaceCoveringRequirements Beton roh
CeilingCovering Pset_SpaceCoveringRequirements Gypsum board ceiling
VibrationRequirements ePset_SpaceRequirement ISO Workshop
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Restricted
RelativeHumidityMin ePset_SpaceRequirement 40 %
RelativeHumidityMax ePset_SpaceRequirement 60 %
PeakOccupancy ePset_SpaceRequirement 2 Personen
DailyOperatingHours ePset_SpaceRequirement 2 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 60 m³/h

Equipment

Shelf or Free-standing shelf min. 1, 1 per 4 m² net floor area
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

More room types of this use

Contact

abstract ag