Room type Assembly and culture
Archive room
RT-ST-05
pragmaticBIM.ch/rt-st-05
Room for document and record archives.
Room name code
RN-10-20-01 Archive room
Standard values
| Attribute | Value | Unit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Archive room | |
| Reference Pset_SpaceCommon | NNF | |
| NetPlannedArea ePset_SpaceRequirement | 30 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Beton | |
| WallCovering Pset_SpaceCoveringRequirements | Beton roh | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Workshop | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Restricted | |
| RelativeHumidityMin ePset_SpaceRequirement | 40 | % |
| RelativeHumidityMax ePset_SpaceRequirement | 60 | % |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 2 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |
Equipment
| Shelf or Free-standing shelf | min. 1, 1 per 4 m² net floor area |
Socket outlet
|
min. 1, 1 per 10 m² net floor area |
Light switch
|
1 |
Openings
More room types of this use
-
RT-WH-39
Waste chute
Vertical chute for transferring household waste to a central collection point.
-
RT-WH-40
Exterior waste collection area
Outdoor area for collecting and presenting bagged household waste.
-
RT-WH-41
Underground waste container
Outdoor space allocated to an underground household-waste collection container.