Room type Warehousing and logistics

Maintenance bay

RT-IN-09 pragmaticBIM.ch/rt-in-09

Bay for equipment maintenance.

Room name code

RN-08-20-04 Maintenance bay

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Maintenance bay
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 50 m²
FloorCovering Pset_SpaceCoveringRequirements Beton
WallCovering Pset_SpaceCoveringRequirements Beton roh
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Workshop
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Internal
PeakOccupancy ePset_SpaceRequirement 2 Personen
DailyOperatingHours ePset_SpaceRequirement 4 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 60 m³/h

Equipment

Workbench 1
Shelf 2 (1-4)
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
  • preferred · next to · working (≤ 0.5 m)
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1