Room type Education

Assembly hall

RT-ED-08 pragmaticBIM.ch/rt-ed-08

Large assembly hall for events.

Room name code

RN-06-30-01 Assembly hall

Standard values

Interior spaces

Attribute Value Unit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Assembly hall
Reference Pset_SpaceCommon HNF
NetPlannedArea ePset_SpaceRequirement 300 m²
FloorCovering Pset_SpaceCoveringRequirements Linoleum
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Wood ceiling lining
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Internal
WinterTemperatureMin ePset_SpaceRequirement 20 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 22 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 500 lx
PeakOccupancy ePset_SpaceRequirement 50 Personen
DailyOperatingHours ePset_SpaceRequirement 8 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 1500 m³/h

Equipment

Chair row min. 4, 1 per 6 m² net floor area
Manoeuvring area SIA 500 2 (1-6)
Socket outlet
  • preferred · elevation
  • required · not in clearance of · access
min. 1, 1 per 10 m² net floor area
Light switch
  • required · next to · access (≤ 0.3 m)
  • required · elevation
1

Openings

Interior double door 2 (2-6)
Window 1 (min. 0)

More room types of this use

Contact

abstract ag