Abstellraum Wohnen
RT-WH-29
pragmaticBIM.ch/rt-wh-29
Kleiner Abstellraum innerhalb einer Wohneinheit.
Raumname-Code
RN-01-20-07 Abstellraum Wohnen
Standardwerte
| Attribut | Wert | Einheit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Abstellraum Wohnen | |
| Reference Pset_SpaceCommon | HNF | |
| FloorCovering Pset_SpaceCoveringRequirements | Beton | |
| WallCovering Pset_SpaceCoveringRequirements | Beton roh | |
| CeilingCovering Pset_SpaceCoveringRequirements | Sonstige / unbekannte Deckenbekleidung | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Intern | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 200 | lx |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |