Raumtyp Bildung

Allgemeines WC

RT-HY-04 pragmaticBIM.ch/rt-hy-04

WC für gemischte oder all-gender Nutzung.

Raumname-Code

RN-04-10-04 Allgemeines WC

Standardwerte

Innenräume

Attribut Wert Einheit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Allgemeines WC
Reference Pset_SpaceCommon NNF
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Plattenbelag
CeilingCovering Pset_SpaceCoveringRequirements Metallblech-Deckenbekleidung
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 2 kN/m²
DesignPointLoad ePset_SpaceRequirement 2 kN
SecurityLevel ePset_Space Intern
WinterTemperatureMin ePset_SpaceRequirement 20 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 22 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 300 lx
PeakOccupancy ePset_SpaceRequirement 1 Personen
DailyOperatingHours ePset_SpaceRequirement 1 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 30 m³/h

Weitere Raumtypen dieser Nutzung

Kontakt

abstract ag

Impressum · Picassoplatz 4, 4052 Basel