Timber ventilated facade system
FaCP-TIMBER-VENTILATED
pragmaticBIM.ch/facp-timber-ventilated
Non-load-bearing timber cladding of boards, slats, or wood-based panels mounted in front of the insulated exterior wall. Fixing is by visible or concealed fasteners onto a battened sub-frame that ensures rear ventilation and all-round drying of the cladding.
Tender text
Non-load-bearing timber cladding of boards, slats, or wood-based panels mounted in front of the insulated exterior wall. Fixing is by visible or concealed fasteners onto a battened sub-frame that ensures rear ventilation and all-round drying of the cladding. Suitable for new build and retrofit at low added dead load; surface treatment, end-grain detailing, and the accepted degree of weathering are to be specified.
More products in this family
-
FaCP-FIBER-CEMENT-BOARD
Fibre-cement board facade
Non-load-bearing mineral board cladding of fibre-cement or reinforced cement panels in front of the insulated exterior wall. The boards are cut to size and riveted, screwed, or concealed-fixed to a metal or timber sub-frame with a ventilated cavity and a defined joint pattern.
-
FaCP-RENDER-ETICS-WDVS
Render / ETICS facade system
Non-load-bearing bonded external insulation and render system applied directly onto the load-bearing exterior wall without a ventilated cavity. Insulation boards are adhesive-bonded and mechanically anchored to the substrate and then covered with a reinforced base coat with embedded mesh and a finishing render.
-
FaCP-SYNTHETIC-VENTILATED
Synthetic ventilated facade panel
Non-load-bearing cladding of synthetic panels such as laminates, plastics, or fibre-reinforced composites hung in front of the insulated exterior wall.