Raumtyp Sport

Tribüne

RT-CO-14 pragmaticBIM.ch/rt-co-14

Gestufte Sitz- oder Stehfläche für Zuschauende.

Raumname-Code

RN-07-40-02 Tribüne

Standardwerte

Innenräume

Attribut Wert Einheit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Tribüne
Reference Pset_SpaceCommon HNF
FloorCovering Pset_SpaceCoveringRequirements Beton gestrichen
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metallpaneel-Decke
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Öffentlich
WinterTemperatureMin ePset_SpaceRequirement 16 °C
WinterTemperatureMax ePset_SpaceRequirement 22 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 200 lx
PeakOccupancy ePset_SpaceRequirement 20 Personen
DailyOperatingHours ePset_SpaceRequirement 4 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 600 m³/h

Weitere Raumtypen dieser Nutzung

Kontakt

abstract ag

Impressum · Picassoplatz 4, 4052 Basel