Raumtyp Verkauf

Laderampe

RT-IN-07 pragmaticBIM.ch/rt-in-07

Bereich für Be- und Entladung.

Raumname-Code

RN-08-20-02 Laderampe

Standardwerte

Innenräume

Attribut Wert Einheit
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Laderampe
Reference Pset_SpaceCommon NNF
FloorCovering Pset_SpaceCoveringRequirements Beton
WallCovering Pset_SpaceCoveringRequirements Beton roh
CeilingCovering Pset_SpaceCoveringRequirements Metallpaneel-Decke
VibrationRequirements ePset_SpaceRequirement ISO Workshop
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Intern
PeakOccupancy ePset_SpaceRequirement 2 Personen
DailyOperatingHours ePset_SpaceRequirement 4 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 60 m³/h

Weitere Raumtypen dieser Nutzung

Kontakt

abstract ag

Impressum · Picassoplatz 4, 4052 Basel