Perron
RT-CI-04
pragmaticBIM.ch/rt-ci-04
Plattform zum Ein- und Aussteigen in Züge, Trams oder Busse.
Raumname-Code
RN-03-30-01 Perron
Standardwerte
| Attribut | Wert | Einheit |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Perron | |
| Reference Pset_SpaceCommon | VF | |
| FloorCovering Pset_SpaceCoveringRequirements | Hartbeton | |
| WallCovering Pset_SpaceCoveringRequirements | Sichtbeton | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metallpaneel-Decke | |
| VibrationRequirements ePset_SpaceRequirement | ISO Workshop | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Öffentlich | |
| WinterTemperatureMin ePset_SpaceRequirement | 5 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 30 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 100 | lx |
| PeakOccupancy ePset_SpaceRequirement | 10 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 12 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 300 | m³/h |