← All use cases

Non-load-bearing interior wall

ARC-WALL-INT

Non-load-bearing interior wall for room separation - basis for fire and acoustic performance data.

Description

  • Non-load-bearing partition between interior spaces.
  • Used for coordination, fire and acoustic verification, and component identification.

Modelling guidelines

  • Model storey by storey; split at component and storey boundaries.
  • Set IsExternal=FALSE and LoadBearing=FALSE.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
ObjectType

Kind of interior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
IsExternal

Pset_WallCommon

Marks an interior wall.

Allowed values

  • FALSE - interior wall
LoadBearing

Pset_WallCommon

Marks the wall as non-load-bearing.

Allowed values

  • FALSE - non-load-bearing
PredefinedType

Kind of interior wall.

Allowed values

  • STANDARD - standard wall
  • PARTITIONING - partition wall
  • SOLIDWALL - solid wall
  • ELEMENTEDWALL - elemented wall
  • MOVABLE - movable wall
  • PLUMBINGWALL - plumbing wall
Reference

Pset_WallCommon

Interior wall reference according to the component catalogue.

Status

Pset_WallCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
FireRating

Pset_WallCommon

Fire resistance class of the interior wall according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
AcousticRating

Pset_WallCommon

Weighted sound reduction index Rw [dB] as laboratory/catalogue value - not R'w.

NetSideArea

Qto_WallBaseQuantities

Net side area of the modelled interior wall.

Width

Qto_WallBaseQuantities

Thickness of the modelled interior wall.

m
GrossVolume

Qto_WallBaseQuantities

Gross volume of the modelled interior wall.

CostInterface

ePset_Cost

Cost interface of the component - base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{Mietername} - tenant fit-out, e.g. MAB_Migros
AwardInterface

ePset_Cost

Award package of the component by three-digit BKP code - so interfaces between contractor packages become visible.

Allowed values

  • See value list BKP award package - e.g. 211, 221, 244.
PlanningInterface

ePset_Cost

Planning interface of the component by three-digit BKP code - so responsibilities between planning disciplines become visible.

Allowed values

  • See value list BKP planning package - e.g. 091, 092, 094.
BelowTerrain

ePset_Cost

Marks whether the component is below terrain.

Allowed values

  • TRUE - below terrain
  • FALSE - above terrain
EbkpH

ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • G01.01 - fixed partition

Contact

abstract ag