← All use cases

Wall cladding

ARC-WALL-CLAD

Interior wall cladding as a modelled surface for quantity take-off.

Description

  • Wall surface with defined quality according to the component catalogue.
  • Separate layer, distinct from the load-bearing wall.

Modelling guidelines

  • Model as a separate layer; split at room and component boundaries.
  • Capture surface quality via Reference.
  • Do not model execution details such as connection profiles.
  • Use an IfcMaterial that corresponds to the actual material class.

Attributes

Name Description Unit
ObjectType

Marks the wall cladding.

Allowed values

  • CLADDING - wall cladding
PredefinedType

Marks the wall cladding.

Allowed values

  • CLADDING - wall cladding
IsExternal

Pset_CoveringCommon

Marks an interior wall cladding.

Allowed values

  • FALSE - interior wall cladding
Reference

Pset_CoveringCommon

Surface quality of the wall cladding according to the component catalogue.

Allowed values

  • See value list Wall surface quality.
Status

Pset_CoveringCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary
ElementStatus

ePset_ElementStatus

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
NetArea

Qto_CoveringBaseQuantities

Net area of the modelled wall cladding.

CostInterface

ePset_Cost

Cost interface of the component - base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{Mietername} - tenant fit-out, e.g. MAB_Migros
AwardInterface

ePset_Cost

Award package of the component by three-digit BKP code - so interfaces between contractor packages become visible.

Allowed values

  • See value list BKP award package - e.g. 211, 221, 244.
PlanningInterface

ePset_Cost

Planning interface of the component by three-digit BKP code - so responsibilities between planning disciplines become visible.

Allowed values

  • See value list BKP planning package - e.g. 091, 092, 094.
BelowTerrain

ePset_Cost

Marks whether the component is below terrain.

Allowed values

  • TRUE - below terrain
  • FALSE - above terrain
EbkpH

ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • G03.02 - wall covering