Pitched roof (Rough)

ARC-ROOF-PITCH

Makes the roof form and structural concept spatially verifiable early on and supports reliable permitting and coordination decisions.

Description

  • Coarsely dimensioned pitched roof geometry according to the structural and envelope concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model as a simplified volume or roof surface; pitch according to the sketch concept.
  • Do not model roof build-ups, cladding, or detail connections.
  • During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
  • Use and export the appropriate material from the authoring system.

Attributes

Name Description Unit
Name

Pitched roof designation according to the structural plan.

PredefinedType

Form of the pitched roof.

Allowed values

  • SHED_ROOF - shed roof
  • GABLE_ROOF - gable roof
  • HIP_ROOF - hip roof
  • HIPPED_GABLE_ROOF - hipped gable roof
  • GAMBREL_ROOF - gambrel roof
  • MANSARD_ROOF - mansard roof
  • BARREL_ROOF - barrel roof
  • RAINBOW_ROOF - rainbow roof
  • BUTTERFLY_ROOF - butterfly roof
  • PAVILION_ROOF - pavilion roof
  • DOME_ROOF - dome roof
  • FREEFORM - freeform
LoadBearing

Pset_RoofCommon

Marks the element as a load-bearing component in the architecture model.

Allowed values

  • TRUE - load-bearing component
Status

Pset_RoofCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
ThermalTransmittance

Pset_RoofCommon

Thermal transmittance U [W/(m²·K)] as laboratory/catalogue value of the component.

W/(m²·K)
ElementStatus

ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
CostInterface

ePset_Cost

Cost interface of the component - base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication

ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface

ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
PlanningInterface

ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain

ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
eBKP

ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • C04.05 - pitched roof construction
ProductClass

ePset_Cost

Product class for cost and tender assignment. It may be assigned manually; for consistent tender data, it should preferably be derived from component properties through deterministic automation or AI-assisted mapping.

Allowed values

UnitPrice

ePset_Cost

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

CHF/m²
ReferenceQuantity

ePset_Cost

Authoritative reference quantity used with UnitPrice: Qto_RoofBaseQuantities.GrossArea.

Connection

ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility

ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse

ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId

ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes

ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

HazardType

ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory

ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
GlobalTradeItemNumber

Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

SerialNumber

Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

GrossArea

Qto_RoofBaseQuantities

Gross area of the modelled pitched roof.

m²

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel