Tapered insulation
ARC-ROOF-DRAIN
Tapered insulation on flat roof and balcony as a modelled layer with falls.
Description
- Insulation layer in the roof or balcony build-up that forms the fall for drainage.
- Used to coordinate falls, outlet positions, and connection to downpipes.
Modelling guidelines
- Model as a separate layer on flat roof and balcony; capture falls.
- Derive drainage points from the fall layout; do not forget the balcony.
- Do not model execution details such as gully types or individual insulation boards.
Attributes
| Name | Description | Unit |
|---|---|---|
| PredefinedType |
Marks the tapered insulation. Allowed values
|
|
| ObjectType |
Marks the tapered insulation. Allowed values
Note
|
|
|
IsExternal
Pset_CoveringCommon |
Marks exterior tapered insulation. Allowed values
|
|
|
Reference
Pset_CoveringCommon |
Tapered insulation zone designation according to the coordination plan (e.g. flat roof north, balcony 2nd floor). |
|
|
Status
Pset_CoveringCommon |
Element status for coordination on existing buildings. Allowed values
|
|
|
ElementStatus
ePset_ElementStatus |
Element status for coordination on existing buildings. Allowed values
Note
|
|
|
NetArea
Qto_CoveringBaseQuantities |
Net area of the modelled tapered insulation. |
m² |
|
CostInterface
ePset_Cost |
Cost interface of the component - base building or tenant fit-out. Allowed values
|
|
|
AwardInterface
ePset_Cost |
Award package of the component by three-digit BKP code - so interfaces between contractor packages become visible. Allowed values
|
|
|
PlanningInterface
ePset_Cost |
Planning interface of the component by three-digit BKP code - so responsibilities between planning disciplines become visible. Allowed values
|