← All use cases

Column (Rough)

ARC-COLUMN

Makes point load transfers spatially verifiable early and prevents conflicts with the spatial layout, facade, and building services.

Description

  • Coarsely dimensioned column according to the structural concept.
  • Used for coordination between architecture and structural engineering, not for execution planning.

Modelling guidelines

  • Model storey by storey as a simplified volume using the coordinated dimensions.
  • Set LoadBearing=TRUE; model as a simplified volume without reinforcement or detail connections.
  • During conceptual architectural design, coordinate the dimensions of conceptual structural components with the structural engineer and adopt them in the architecture model.
  • Use and export the appropriate material from the authoring system.

Attributes

Name Description Unit
Name

Column designation according to the structural plan.

PredefinedType

Kind of column.

Allowed values

  • COLUMN - column
  • PILASTER - pilaster (flat column engaged with a wall)
LoadBearing

Pset_ColumnCommon

Marks the column as a load-bearing element in the architecture model.

Allowed values

  • TRUE - load-bearing element
Status

Pset_ColumnCommon

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary
FireRating

Pset_ColumnCommon

Fire resistance class of the column according to the fire protection concept.

Allowed values

  • R 30 - load-bearing 30 min
  • R 60 - load-bearing 60 min
  • R 90 - load-bearing 90 min
  • EI 30 - integrity and insulation 30 min
  • EI 60 - integrity and insulation 60 min
  • EI 90 - integrity and insulation 90 min
  • REI 30 - load-bearing, integrity and insulation 30 min
  • REI 60 - load-bearing, integrity and insulation 60 min
  • REI 90 - load-bearing, integrity and insulation 90 min
IsExternal

Pset_ColumnCommon

Marks whether the column is exterior or interior.

Allowed values

  • TRUE - exterior column
  • FALSE - interior column
ElementStatus

ePset_ElementStatus

Component status for coordinating work in existing buildings.

Allowed values

  • NEW - new build
  • EXISTING - existing
  • DEMOLISH - demolition
  • TEMPORARY - temporary

Note

  • IFC2x3 substitute for Status.
Profilname

ePset_Cost

Profile designation for the calculated type name, e.g. HEA200.

Width

ePset_Cost

Width of the modelled column cross-section.

m
Height

ePset_Cost

Height of the modelled column cross-section.

m
CostInterface

ePset_Cost

Cost interface of the component - base building or tenant fit-out.

Allowed values

  • GAB - base building (client / landlord)
  • MAB_{TenantName} - tenant fit-out, e.g. MAB_TenantA
FundingApplication

ePset_Cost

Number of the funding application, so quantities and costs can be filtered by application. Separate several numbers with commas, e.g. 2024-0142, 2024-0188. Leave empty when the component belongs to no application.

AwardInterface

ePset_Cost

Procurement package of the component, so interfaces between contractor packages become visible.

Allowed values

  • See the Procurement package value list. This Swiss data package uses three-digit BKP codes, e.g. 211, 221, 244.
PlanningInterface

ePset_Cost

Planning interface of the component as a three-digit BKP code, so responsibilities between design disciplines become visible.

Allowed values

  • See the BKP planning package value list, e.g. 091, 092, 094.
BelowTerrain

ePset_Cost

Marks whether the component sits below ground level.

Allowed values

  • TRUE - below ground
  • FALSE - above ground
eBKP

ePset_Cost

eBKP-H classification according to SN 506 511 - derivable from IsExternal, LoadBearing, and BelowTerrain.

Allowed values

  • C03.01 - exterior column
  • C03.02 - interior column
CalculatedType

ePset_Cost

Calculated type name for cost and quantity grouping. Logic StuetzeTypisierung. Example: Stütze_Stahl_HEA200_200x200_3.20m

ProductClass

ePset_Cost

Product class for cost and tender assignment. It may be assigned manually; for consistent tender data, it should preferably be derived from component properties through deterministic automation or AI-assisted mapping.

Allowed values

UnitPrice

ePset_Cost

Project- or office-specific unit price per unit of the reference quantity, used to check component costs for plausibility.

CHF/m³
ReferenceQuantity

ePset_Cost

Authoritative reference quantity used with UnitPrice: Qto_ColumnBaseQuantities.GrossVolume.

Connection

ePset_Circularity

Connection type for detachability (Madaster).

Allowed values

  • DryConnection - dry connection
  • AddedConnection - connection using added parts
  • DirectConnection - direct integral connection
  • SoftChemicalConnection - soft chemical connection
  • HardChemicalConnection - hard chemical connection
Accessibility

ePset_Circularity

Accessibility of the connection without destroying the component or surroundings (Madaster).

Allowed values

  • Accessible - freely accessible without additional actions
  • PartialNoDamage - accessible with actions that cause no damage
  • PartialWithRepairableDamage - accessible with fully repairable damage
  • PartialWithDamage - accessible with partially repairable damage
  • NotAccessible - not accessible; irreparable damage
Reuse

ePset_Circularity

Share of already reused or recycled material in the component (0.01 - 1.00, e.g. 0.80 = 80 %).

MaterialOrProductId

ePset_Circularity

Unique ID of the material or product in the linked database (e.g. Madaster, baubook).

WasteCodes

ePset_Circularity

Waste codes for deconstruction and disposal. Code to VeVA (CH) or EWC/AVV (EU); format as used by Madaster, e.g. 17 01:0.25:Inert:60:60;.

HazardType

ePset_HazardousMaterial

Type of hazardous material found by survey on the affected existing component.

Allowed values

  • Asbestos - asbestos
  • PCB - PCB
  • PAH - PAH
  • PCP - PCP
  • Lead - lead
  • None - no hazardous material
  • Unknown - unknown / not investigated
RemovalCategory

ePset_HazardousMaterial

Remediation urgency and action required, as determined by the survey.

Allowed values

  • Immediate - remediate immediately
  • PriorToDemolition - remediate before demolition or alteration
  • InSitu - may remain in place, under monitoring
  • None - no action required
GlobalTradeItemNumber

Pset_ManufacturerTypeInformation

GTIN (Global Trade Item Number) of the product type; 8, 12, 13, or 14 digits depending on the GS1 structure.

SerialNumber

Pset_ManufacturerOccurrence

Serial number the manufacturer assigns to an individual product; with the GTIN it identifies the product passport for that specific item.

GrossVolume

Qto_ColumnBaseQuantities

Gross volume of the modelled column.

m³
Length

Qto_ColumnBaseQuantities

Length of the modelled column.