Locale di asciugatura
RT-WH-38
pragmaticBIM.ch/rt-wh-38
Locale per asciugare il bucato, distinto dal locale di lavaggio.
Codice nome locale
RN-01-20-11 Locale di asciugatura
Valori standard
| Attributo | Valore | Unità |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Locale di asciugatura | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 8 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Interno | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 200 | lx |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
Attrezzatura
Presa
|
min. 1, 1 per 10 m² di superficie netta di piano |
Interruttore della luce
|
1 |
Aperture
| Porta a battente interna | 1 |
| Finestra | 1 (min. 0) |
Altri tipi di locale di questa destinazione d'uso
-
RT-ST-11
Locale passeggini
Locale per passeggini e ausili alla mobilità, attiguo all'atrio, fuori dal percorso di fuga.
-
RT-ST-12
Locale pacchi
Locale per armadietti pacchi, distinto dal locale posta e dagli armadietti personali.
-
RT-WH-39
Condotto rifiuti
Condotto verticale per convogliare i rifiuti domestici verso un punto di raccolta centrale.