Tipo di locale Abitazione

Zona ascensore

RT-WH-13 pragmaticBIM.ch/rt-wh-13

Zona antistante l'ascensore a un piano.

Codice nome locale

RN-03-20-02 Zona ascensore

Valori standard

Spazi interni

Attributo Valore Unità
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Zona ascensore
Reference Pset_SpaceCommon VF
NetPlannedArea ePset_SpaceRequirement 6 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Interno
WinterTemperatureMin ePset_SpaceRequirement 16 °C
WinterTemperatureMax ePset_SpaceRequirement 20 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 100 lx
PeakOccupancy ePset_SpaceRequirement 10 Personen
DailyOperatingHours ePset_SpaceRequirement 12 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 300 m³/h