Ingresso dell'alloggio
RT-WH-01
pragmaticBIM.ch/rt-wh-01
Zona d'ingresso all'interno di un'unità abitativa.
Codice nome locale
RN-01-20-06 Ingresso dell'alloggio
Valori standard
| Attributo | Valore | Unità |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Ingresso dell'alloggio | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 2 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Schmutzschleuse | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Interno | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 100 | lx |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |
Attrezzatura
| Guardaroba | 1 (0-1) |
| Area di manovra SIA 500 a seconda delle decisioni di progetto | 1 |
Presa
|
min. 1, 1 per 10 m² di superficie netta di piano |
Interruttore della luce
|
1 |