Locale controllo qualità
RT-IN-08
pragmaticBIM.ch/rt-in-08
Locale per il controllo e la verifica della qualità.
Codice nome locale
RN-08-20-03 Locale controllo qualità
Valori standard
| Attributo | Valore | Unità |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Locale controllo qualità | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 30 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Linoleum | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Mineral-fibre acoustic ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Interno | |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 10 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |
Attrezzatura
| Tavolo da lavoro | min. 1, 1 per 8 m² di superficie netta di piano |
| Postazione di lavoro d'ufficio | 1 |
Presa
|
min. 1, 1 per 10 m² di superficie netta di piano |
Interruttore della luce
|
1 |
Aperture
| Porta a battente interna oppure Porta a due ante interna | 1 |
| Finestra | 1 (min. 1) |