Tipo di locale Trasporto passeggeri

Rampa

RT-CI-03 pragmaticBIM.ch/rt-ci-03

Accesso inclinato privo di barriere.

Codice nome locale

RN-03-20-03 Rampa

Valori standard

Spazi interni

Attributo Valore Unità
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Rampa
Reference Pset_SpaceCommon VF
NetPlannedArea ePset_SpaceRequirement 30 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Office
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Interno
WinterTemperatureMin ePset_SpaceRequirement 16 °C
WinterTemperatureMax ePset_SpaceRequirement 20 °C
SummerTemperatureMin ePset_SpaceRequirement 20 °C
SummerTemperatureMax ePset_SpaceRequirement 28 °C
RequiredIlluminance ePset_SpaceRequirement 100 lx
PeakOccupancy ePset_SpaceRequirement 10 Personen
DailyOperatingHours ePset_SpaceRequirement 12 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 300 m³/h

Attrezzatura

Presa
  • preferito · elevation
min. 1, 1 per 10 m² di superficie netta di piano
Interruttore della luce
  • richiesto · elevation
1

Altri tipi di locale di questa destinazione d'uso

Contact

abstract ag

Imprint · Picassoplatz 4, 4052 Basel