Local de séchage
RT-WH-38
pragmaticBIM.ch/rt-wh-38
Local pour le séchage du linge, distinct du local de lavage.
Code du nom de local
RN-01-20-11 Local de séchage
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Local de séchage | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 8 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Interne | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 200 | lx |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
Équipement
Prise
|
min. 1, 1 pour 10 m² de surface nette de plancher |
Interrupteur d'éclairage
|
1 |
Ouvertures
| Porte battante intérieure | 1 |
| Fenêtre | 1 (min. 0) |
Autres types de locaux de cette affectation
-
RT-ST-11
Local à poussettes
Local pour poussettes et aides à la mobilité, attenant au hall d'entrée, hors du chemin de fuite.
-
RT-ST-12
Local à colis
Local à casiers pour colis, distinct du local courrier et des casiers personnels.
-
RT-WH-39
Gaine vide-ordures
Gaine verticale destinée à acheminer les déchets ménagers vers un point de collecte central.