Type de local Habitation

Local à poussettes

RT-ST-11 pragmaticBIM.ch/rt-st-11

Local pour poussettes et aides à la mobilité, attenant au hall d'entrée, hors du chemin de fuite.

Code du nom de local

RN-10-10-06 Local à poussettes

Valeurs standard

Espaces intérieurs

Attribut Valeur Unité
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Local à poussettes
Reference Pset_SpaceCommon NNF
NetPlannedArea ePset_SpaceRequirement 4 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Gypsum board ceiling
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 5 kN/m²
DesignPointLoad ePset_SpaceRequirement 4 kN
SecurityLevel ePset_Space Restreint
PeakOccupancy ePset_SpaceRequirement 1 Personen
DailyOperatingHours ePset_SpaceRequirement 1 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 30 m³/h

Équipement

Prise
  • préféré · elevation
  • requis · hors dégagement de · accès
min. 1, 1 pour 10 m² de surface nette de plancher
Interrupteur d'éclairage
  • requis · à côté de · accès (≤ 0.3 m)
  • requis · elevation
1

Ouvertures

Autres types de locaux de cette affectation

Contact

abstract ag