Type de local Habitation

Couloir commun

RT-WH-20 pragmaticBIM.ch/rt-wh-20

Circulation commune hors des logements.

Code du nom de local

RN-03-10-01 Couloir commun

Valeurs standard

Espaces intérieurs

Attribut Valeur Unité
PredefinedType SPACE
IsExternal Pset_SpaceCommon FALSE
LongName Couloir commun
Reference Pset_SpaceCommon VF
NetPlannedArea ePset_SpaceRequirement 20 m²
FloorCovering Pset_SpaceCoveringRequirements Plattenbelag
WallCovering Pset_SpaceCoveringRequirements Anstrich
CeilingCovering Pset_SpaceCoveringRequirements Metal panel ceiling
VibrationRequirements ePset_SpaceRequirement ISO Residential (Night)
InteriorOrExteriorSpace INTERNAL
DesignAreaLoad ePset_SpaceRequirement 4 kN/m²
DesignPointLoad ePset_SpaceRequirement 3 kN
SecurityLevel ePset_Space Interne
WinterTemperatureMin ePset_SpaceRequirement 20 °C
WinterTemperatureMax ePset_SpaceRequirement 24 °C
SummerTemperatureMin ePset_SpaceRequirement 22 °C
SummerTemperatureMax ePset_SpaceRequirement 26 °C
RequiredIlluminance ePset_SpaceRequirement 100 lx
PeakOccupancy ePset_SpaceRequirement 10 Personen
DailyOperatingHours ePset_SpaceRequirement 12 h/Tag
OutdoorAirFlowRate ePset_SpaceRequirement 300 m³/h

Équipement

Prise
  • préféré · elevation
min. 1, 1 pour 10 m² de surface nette de plancher
Interrupteur d'éclairage
  • requis · elevation
1