Local courrier
RT-WH-14
pragmaticBIM.ch/rt-wh-14
Local pour la réception et la distribution du courrier.
Code du nom de local
RN-10-20-02 Local courrier
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Local courrier | |
| Reference Pset_SpaceCommon | NNF | |
| NetPlannedArea ePset_SpaceRequirement | 4 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Gypsum board ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Residential (Night) | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Restreint | |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
Équipement
| Casiers et vestiaires | 1 |
Prise
|
min. 1, 1 pour 10 m² de surface nette de plancher |
Interrupteur d'éclairage
|
1 |