Local de contrôle qualité
RT-IN-08
pragmaticBIM.ch/rt-in-08
Local pour le contrôle et l'assurance qualité.
Code du nom de local
RN-08-20-03 Local de contrôle qualité
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Local de contrôle qualité | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 30 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Linoleum | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Mineral-fibre acoustic ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Interne | |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 10 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |
Équipement
| Table de travail | min. 1, 1 pour 8 m² de surface nette de plancher |
| Poste de travail de bureau | 1 |
Prise
|
min. 1, 1 pour 10 m² de surface nette de plancher |
Interrupteur d'éclairage
|
1 |
Ouvertures
| Porte battante intérieure ou Porte à deux vantaux intérieure | 1 |
| Fenêtre | 1 (min. 1) |