WC visiteurs
RT-HY-10
pragmaticBIM.ch/rt-hy-10
WC pour les visiteurs et la clientèle, séparé du personnel.
Code du nom de local
RN-04-10-07 WC visiteurs
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | WC visiteurs | |
| Reference Pset_SpaceCommon | NNF | |
| NetPlannedArea ePset_SpaceRequirement | 15 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal sheet ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 2 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 2 | kN |
| SecurityLevel ePset_Space | Interne | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 300 | lx |
| PeakOccupancy ePset_SpaceRequirement | 1 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 1 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 30 | m³/h |
Équipement
| WC suspendu | 3 (min. 1) |
| Rangée de lavabos ou Lavabo | 1 |
| Prise | min. 1, 1 pour 10 m² de surface nette de plancher |
| Interrupteur d'éclairage | 1 |