Auditoire
RT-ED-02
pragmaticBIM.ch/rt-ed-02
Local à sièges fixes pour les cours magistraux.
Code du nom de local
RN-06-10-02 Auditoire
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Auditoire | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 200 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Linoleum | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Wood ceiling lining | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 4 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Interne | |
| WinterTemperatureMin ePset_SpaceRequirement | 20 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 24 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 500 | lx |
| PeakOccupancy ePset_SpaceRequirement | 50 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 8 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 1500 | m³/h |
Équipement
| Rangée de sièges avec tablette | min. 2, 1 pour 10 m² de surface nette de plancher |
| Poste de travail de bureau | 1 |
| Tableau mural | 1 |
| Aire de manœuvre SIA 500 | 2 (1-4) |
Prise
|
min. 1, 1 pour 10 m² de surface nette de plancher |
Interrupteur d'éclairage
|
1 |
Ouvertures
| Porte à deux vantaux intérieure | 2 (2-4) |
| Fenêtre | 1 (min. 0) |