Point de retrait
RT-CO-17
pragmaticBIM.ch/rt-co-17
Comptoir ou espace où la clientèle retire les marchandises commandées ou achetées.
Code du nom de local
RN-07-20-06 Point de retrait
Valeurs standard
| Attribut | Valeur | Unité |
|---|---|---|
| PredefinedType | SPACE | |
| IsExternal Pset_SpaceCommon | FALSE | |
| LongName | Point de retrait | |
| Reference Pset_SpaceCommon | HNF | |
| NetPlannedArea ePset_SpaceRequirement | 10 | m² |
| FloorCovering Pset_SpaceCoveringRequirements | Plattenbelag | |
| WallCovering Pset_SpaceCoveringRequirements | Anstrich | |
| CeilingCovering Pset_SpaceCoveringRequirements | Metal panel ceiling | |
| VibrationRequirements ePset_SpaceRequirement | ISO Office | |
| InteriorOrExteriorSpace | INTERNAL | |
| DesignAreaLoad ePset_SpaceRequirement | 5 | kN/m² |
| DesignPointLoad ePset_SpaceRequirement | 4 | kN |
| SecurityLevel ePset_Space | Public | |
| WinterTemperatureMin ePset_SpaceRequirement | 18 | °C |
| WinterTemperatureMax ePset_SpaceRequirement | 22 | °C |
| SummerTemperatureMin ePset_SpaceRequirement | 20 | °C |
| SummerTemperatureMax ePset_SpaceRequirement | 26 | °C |
| RequiredIlluminance ePset_SpaceRequirement | 300 | lx |
| PeakOccupancy ePset_SpaceRequirement | 2 | Personen |
| DailyOperatingHours ePset_SpaceRequirement | 10 | h/Tag |
| OutdoorAirFlowRate ePset_SpaceRequirement | 60 | m³/h |
Équipement
| Casiers et vestiaires | min. 1, 1 pour 3 m² de surface nette de plancher |
Prise
|
min. 1, 1 pour 10 m² de surface nette de plancher |
Interrupteur d'éclairage
|
1 |
Ouvertures
Autres types de locaux de cette affectation
-
RT-CI-06
Monte-charge
Ascenseur pour marchandises, personnel et circulations de service, séparé des ascenseurs publics.
-
RT-WH-45
Compost commun
Aire extérieure où les habitants compostent ensemble les déchets organiques.
-
RT-HY-08
WC enseignants
WC pour les enseignants, séparé des élèves et des étudiants.