← All use cases

Exclusion zone

STR-EXCL-ZONE

Exclusion zone in the structural engineering exclusion zone model.

Description

  • Volume where architecture and building services must not place anything (for example column axis, beam zone, opening reserve).
  • Delivered by the structural engineer as a binding planning boundary, not modelled by the architect.

Modelling guidelines

  • Model as a simplified proxy body; dimensions according to the structural design.
  • Assign to the matching storey.
  • Do not model reinforcement, execution details, or load-bearing components.

Attributes

Name Description Unit
PredefinedType

Marks the proxy as a user-defined type.

Allowed values

  • USERDEFINED - user-defined type; ObjectType specifies the kind
ObjectType

Kind of proxy element.

Allowed values

  • Sperrzone - no-go zone according to the structural design
Reference

Pset_BuildingElementProxyCommon

Reference used for identification in the coordination model.

Name

Exclusion zone designation according to the structural design.

Contact

abstract ag