← All use cases

Storey

STOREY

Description

  • Horizontal building level: usable storeys and foundation.
  • Assigned to the building.

Modelling guidelines

  • Each usable level as its own storey.
  • Foundation as its own storey named FD or GR; assign foundation elements to this storey.
  • Assign spaces to the matching storey.
  • Name according to storey classification, unique per building.

Attributes

Name Description Unit
Name

Unique storey code according to storey classification, once per building.

Allowed values

  • FD or GR - foundation; model as its own storey
  • U01 - U99 - basement; number increases downward (U01 = 1st basement directly below ground floor)
  • 00 or EG - ground floor
  • 01 - 99 - upper floor; number increases upward
  • Z00 or {storey}.Z - mezzanine (e.g. 01.Z above storey 01)

e.g. FD, U01, EG, 03, 01.Z