Interior spaces

SPACE-INT

Enclosed, walkable room volumes within the building.

Description

  • Usable interior spaces modelled as continuous volumes.
  • Room use is carried in LongName; Name may carry the room number.

Modelling guidelines

  • Model as a volume with the space tool, storey by storey.
  • From top of finished floor to underside of the structural ceiling - not a suspended ceiling. Only then can the space be reused by other trades.
  • No overlaps or duplicates.

Attributes

Name Description Unit
PredefinedType

Marks the space as interior.

Allowed values

  • INTERNAL - interior space
InteriorOrExteriorSpace

Marks the space as interior.

Allowed values

  • INTERNAL - interior space

Note

  • IFC2x3 substitute for PredefinedType and IsExternal.
LongName

Normalized room use for interior spaces according to Pragmatic BIM Building Space Name Classification v0.2.0.

Source

  • https://schema.pragmaticbim.ch/classification/room-name.html

Allowed values

  • See value list Room name interior space v0.2.0 - RN notation.
Name

Unique technical room number for planning. It should stay stable as long as:

  • the room size does not change substantially (e.g. from 12 m² office to 25 m² open-plan office)
  • the function does not change substantially (e.g. from office to meeting room)
  • and the orientation does not change (e.g. from south to east facing)

Do not use for signage - signage room numbers change often and belong in SignageRoomNumber.

SignageRoomNumber

ePset_SpaceSignage

Room number for wayfinding signage (labelling, orientation). Separate from the technical planning room number (Name), because signage numbers often change and frequently differ from the planning number.

Reference

Pset_SpaceCommon

Area class of the space according to SIA 416 or SIA D0165.

Source

  • SIA 416: https://schema.pragmaticbim.ch/classification/mapping-room-activity-to-sia416.html
  • SIA D0165: https://schema.pragmaticbim.ch/classification/mapping-room-activity-to-d0165.html

Allowed values

  • See value list Space reference interior SIA 416 / D0165 - e.g. HNF, NNF, VF (SIA 416) or HNF-1, NNF-7, VF-9 (D0165).
IsExternal

Pset_SpaceCommon

Marks an interior space.

Allowed values

  • FALSE - interior space
NetFloorArea

Qto_SpaceBaseQuantities

Net floor area of the modelled space.

NetVolume

Qto_SpaceBaseQuantities

Net volume of the modelled space.

Height

Qto_SpaceBaseQuantities

Height of the modelled space volume.

m
FinishCeilingHeight

Qto_SpaceBaseQuantities

Suspended ceiling height - clear height from top of finished floor to underside of the suspended ceiling.

Note

  • For an uneven suspended ceiling, pick the worst case for use: the deepest underside (smallest clear height).
m
FloorCovering

Pset_SpaceCoveringRequirements

Floor covering type for early planning - as a space property only, without a modelled floor build-up.

Allowed values

  • See value list Space floor covering type.
DesignAreaLoad

ePset_SpaceUsageAgreement

Agreed design area load for the usage agreement (SIA 260).

kN/m²
DesignPointLoad

ePset_SpaceUsageAgreement

Agreed design point load for the usage agreement (SIA 260).

kN
VibrationRequirements

ePset_SpaceUsageAgreement

Agreed vibration requirements for the usage agreement (SIA 260) as Vibration Criterion (VC).

Allowed values

  • See value list Vibration criterion VC.
Checkliste

ePset_SpaceFitOut

Free-text description of fit-out work in the room including sequence - so contractors on site can see what needs to be done.