Interior spaces
SPACE-INT
Enclosed, walkable room volumes within the building.
Description
- Usable interior spaces modelled as continuous volumes.
- Room use is carried in LongName; Name may carry the room number.
Modelling guidelines
- Model as a volume with the space tool, storey by storey.
- From top of finished floor to underside of the structural ceiling - not a suspended ceiling. Only then can the space be reused by other trades.
- No overlaps or duplicates.
Attributes
| Name | Description | Unit |
|---|---|---|
| PredefinedType |
Marks the space as interior. Allowed values
|
|
| InteriorOrExteriorSpace |
Marks the space as interior. Allowed values
Note
|
|
| LongName |
Normalized room use for interior spaces according to Pragmatic BIM Building Space Name Classification v0.2.0. Source
Allowed values
|
|
| Name |
Unique technical room number for planning. It should stay stable as long as:
Do not use for signage - signage room numbers change often and belong in SignageRoomNumber. |
|
|
SignageRoomNumber
ePset_SpaceSignage |
Room number for wayfinding signage (labelling, orientation). Separate from the technical planning room number (Name), because signage numbers often change and frequently differ from the planning number. |
|
|
Reference
Pset_SpaceCommon |
Area class of the space according to SIA 416 or SIA D0165. Source
Allowed values
|
|
|
IsExternal
Pset_SpaceCommon |
Marks an interior space. Allowed values
|
|
|
NetFloorArea
Qto_SpaceBaseQuantities |
Net floor area of the modelled space. |
m² |
|
NetVolume
Qto_SpaceBaseQuantities |
Net volume of the modelled space. |
m³ |
|
Height
Qto_SpaceBaseQuantities |
Height of the modelled space volume. |
m |
|
FinishCeilingHeight
Qto_SpaceBaseQuantities |
Suspended ceiling height - clear height from top of finished floor to underside of the suspended ceiling. Note
|
m |
|
FloorCovering
Pset_SpaceCoveringRequirements |
Floor covering type for early planning - as a space property only, without a modelled floor build-up. Allowed values
|
|
|
DesignAreaLoad
ePset_SpaceUsageAgreement |
Agreed design area load for the usage agreement (SIA 260). |
kN/m² |
|
DesignPointLoad
ePset_SpaceUsageAgreement |
Agreed design point load for the usage agreement (SIA 260). |
kN |
|
VibrationRequirements
ePset_SpaceUsageAgreement |
Agreed vibration requirements for the usage agreement (SIA 260) as Vibration Criterion (VC). Allowed values
|
|
|
Checkliste
ePset_SpaceFitOut |
Free-text description of fit-out work in the room including sequence - so contractors on site can see what needs to be done. |