Exterior spaces
SPACE-EXT
Usable room volumes located outside the building.
Description
- Exterior spaces such as balconies, terraces, and treated surroundings.
- Room use is carried in LongName; Name may carry the room number.
Modelling guidelines
- Model as a volume outside the building.
- Assign balconies and terraces to the matching storey.
- Best practice: model exterior spaces only 1 m high to visually distinguish them from interior spaces quickly.
Attributes
| Name | Description | Unit |
|---|---|---|
| PredefinedType |
Marks the space as exterior. Allowed values
|
|
| InteriorOrExteriorSpace |
Marks the space as exterior. Allowed values
Note
|
|
| LongName |
Normalized room use for exterior spaces according to Pragmatic BIM Building Space Name Classification v0.2.0. Source
Allowed values
|
|
| Name |
Unique technical room number for planning. It should stay stable as long as:
Do not use for signage - signage room numbers change often and belong in SignageRoomNumber. |
|
|
SignageRoomNumber
ePset_SpaceSignage |
Room number for wayfinding signage (labelling, orientation). Separate from the technical planning room number (Name), because signage numbers often change and frequently differ from the planning number. |
|
|
IsExternal
Pset_SpaceCommon |
Marks an exterior space. Allowed values
|
|
|
Reference
Pset_SpaceCommon |
Area class of the exterior space according to SIA 416 or SIA D0165. Source
Allowed values
|
|
|
NetFloorArea
Qto_SpaceBaseQuantities |
Net floor area of the modelled exterior space. |
m² |
|
NetVolume
Qto_SpaceBaseQuantities |
Net volume of the modelled exterior space. |
m³ |
|
Height
Qto_SpaceBaseQuantities |
Height of the modelled exterior space volume. |
m |
|
DesignAreaLoad
ePset_SpaceUsageAgreement |
Agreed design area load for the usage agreement (SIA 260). |
kN/m² |
|
DesignPointLoad
ePset_SpaceUsageAgreement |
Agreed design point load for the usage agreement (SIA 260). |
kN |
|
VibrationRequirements
ePset_SpaceUsageAgreement |
Agreed vibration requirements for the usage agreement (SIA 260) as Vibration Criterion (VC). Allowed values
|