← All use cases

Waste terminal

MEP-WASTE

Description

  • Wastewater outlet or drain terminal in the building.
  • Floor drain; sink drain; WC outlet.

Modelling guidelines

  • Model as an equipment object with size and location.
  • Assign to the matching storey and technical or use zone.

Attributes

Name Description Unit
PredefinedType

Kind of equipment or terminal.

Allowed values

  • FLOORWASTE - floor waste
  • FLOORTRAP - floor trap
  • GULLYTRAP - gully trap
  • GULLYSUMP - gully sump
  • WASTETRAP - waste trap
  • WASTEDISPOSALUNIT - waste disposal unit
  • ROOFDRAIN - roof drain
Tag

Plant identification (AKS) according to the client standard.

If no project-specific standard exists, suggestion: {Building}-{Storey}-{Trade}-{Plant type}-{nnn} (e.g. B01-02-H-RLT-003).

WarrantyEndDate

Pset_Warranty

Warranty end date - to be provided by the contractor.

DatasheetLink

ePset_ProductData

Link (URI) to the product datasheet.

Status

Pset_WasteTerminalTypeCommon

Element status for coordination on existing buildings.

Allowed values

  • NEW - new
  • EXISTING - existing
  • DEMOLISH - to demolish
  • TEMPORARY - temporary

Contact

abstract ag